ACADEMY
Technical Information
Mechanism of Air Filtration
Air filtration works by eliminating harmful particles and contaminants from the air we breathe. This process combines physical and chemical methods to ensure the air is free from allergens, dust, and other pollutants. The primary mechanisms involved in air filtration are:
Is It Logical to Wash Dust Collection Cartridge Filters?
In industrial settings, it may seem cost-effective to wash and reuse dust collection cartridge filters due to budget constraints or attempts to extend the filter change cycle. However, this practice is generally ill-advised for several reasons.
Sealing and Surface Importance for the Leakage Effect at HEPA Filters
HEPA filter housing sealing and surface compatibility are critical for ensuring a tight seal between the filter and the housing, preventing any unfiltered air from bypassing the system. The effectiveness of these gaskets relies heavily on the compatibility and quality of both the gasket material and the housing’s gasket pressing surface.
Principle of Dehumidification
The principle of dehumidification involves lowering the amount of moisture or humidity in a certain environment. This is often achieved through methods such as condensation, absorption, or chemical dehumidification.
Filter Class Comparison Chart
ATEX, an acronym derived from “Atmospheres Explosible,” refers to the European Parliament Directive 94/9/EC, updated under the ATEX 2014/34/EU Guidelines. This directive primarily establishes manufacturing standards to ensure the quality and safety of protective systems designed for use in potentially explosive atmospheres.
ATEX ATmospheres EXplosible
ATEX, an acronym derived from “Atmospheres Explosible,” refers to the European Parliament Directive 94/9/EC, updated under the ATEX 2014/34/EU Guidelines. This directive primarily establishes manufacturing standards to ensure the quality and safety of protective systems designed for use in potentially explosive atmospheres.
Comparison of Cleanroom Standards
The Comparison of Cleanroom Standards table provides a detailed analysis of various international cleanroom standards, including U.S.209E 1992, ISO 14644-1 1997, EEC GGMP 1989, VDI 2083 1990, BS 5295 1989, and JACA B 9920 1989.
Why Dehumidification?
Dehumidification is the process of removing moisture from the air to regulate humidity levels in indoor spaces. High humidity levels can cause a range of problems, including mold and mildew growth, structural damage, and health issues.
Correct Filter Media Selection
Filter Paper Media Selection is a tool that helps consumers choose the right filter paper for their specific filtration needs. Whether you are filtering gases or air, this product offers a variety of options to meet your filtering requirements.
Dust Collector Discharge Mechanism
With the dust collection discharge mechanism, you can achieve a cleaner and healthier workspace. It is a must-have for any industrial facility that requires a reliable and efficient dust collection system.
Explosive Dust Classification
With explosive dust classification, you can reduce risks and ensure the safety of your employees and equipment, creating a safer and more productive work environment for all. Get in touch today to learn more about how explosive dust classification can benefit your business.
Understanding Psychrometric Chart
A psychrometric chart is a graphical representation of air properties and their relationships with each other. It is used to determine air conditions such as temperature, humidity, and relative humidity, as well as the dew point and enthalpy of air.
Why Cartridge Filter?
Cartridge filters are a popular choice for water filtration due to their effectiveness and low maintenance. They are designed to trap impurities and sediment in the water, preventing them from entering your home or appliances
Principle Of Dust Collection
The principle of dust collection involves capturing and removing airborne dust particles from a work environment. This is typically done using a combination of exhaust fans, ductwork, and air filters to create negative pressure that draws.
Cross Contamination Control
Cross-contamination control in the pharmaceutical industry is critical to ensuring product safety, quality, and compliance with regulatory standards
Humidity Control for
Eye Surgery
Eye laser surgery control, direct links to the quality of surgery and patient care.
Venturi Nozzle
A Venturi nozzle increases fluid speed by reducing pressure with a narrow throat surrounded by convergent and divergent sections. It has many applications and is used in HVAC, water treatment, and aerospace.
Optimal Laminar Flow Air Velocity
In cleanroom environments, the typical velocity range for laminar flow is 0.36 to 0.45 meters per second (m/s).
Dehumidification For Glass Lamination Process
Glass laminating room humidity and dust control direct links of the product.
Industrial Ventilation Systems
Industrial ventilation is a system that aims to protect the health of employees by improving air quality in workplaces and removing harmful gases, dust and vapors.